The chimney report in your sale, read line by line

Book a Level 2 for a sale

Page one: the cover sheet

The first page of our report is short on purpose. It names the property, the date, the inspection level and the standard it follows, NFPA 211. It lists every fireplace, stove and vent we looked at, so nobody later wonders whether the den fireplace was included. Below that sits a one line verdict for each one: usable as is, usable with items to address, or not to be used until repaired.

If you read nothing else, read that verdict line and the list of appliances. A buyer in Garden Grove who sees two fireplaces in the listing but only one on our cover sheet should ask why before the contingency closes.

Pages two and three: the flue on camera

This is the part a general home inspector cannot give you. We run a camera from the firebox or the top down through the whole flue and pull still frames of anything that matters to the verdict. Each frame is labeled with its height in the chimney and what it shows: a cracked tile, a joint with mortar missing, glaze from heavy wood burning, or a clean run of liner.

Beside each image is a sentence in plain words. A gap between two clay tiles, for example, is a code failure for a wood fire because heat can reach the framing through it. A light coat of soot is not. The words tell you which is which, so you do not have to judge the photo yourself.

  • Tile cracks and offsets, with their height
  • Gaps in the smoke chamber above the damper
  • Signs of a past flue fire
  • The liner or bare tile at the top

The last page: what it means for the deal

Every finding ends in one of three ratings, and the ratings are what agents use. Items that block use until fixed are the ones a buyer usually raises in a repair request. Items to address soon are often handled with a credit. Items to watch are recorded so the next owner knows they were seen.

Where a repair has a published price, the report says so. Where it does not, we write a separate quote so it can be attached to the request without editing the report. A seller who wants to get ahead of the buyer can order the same Level 2 before listing and decide which items to fix, which to price into the sale and which to disclose.

What the report costs

The camera inspection behind this report is a fixed price for the house, booked by either side of the sale.

Sale report with camera footage of the flue
$410
Visual walk round only, no camera
$170

If a buyer only needs a quick visual read on a newer house, the Level 1 is listed too, but for a change of owner NFPA 211 points to the Level 2.

Escrow questions about the Level 2 report

Why does a sale call for the camera level?

Because the new owner has no history for the chimney. NFPA 211 names a change of ownership as a reason for a Level 2, and the camera is the only way to see the whole flue.

Who receives the report?

Whoever books the visit, plus any agents or others they name when booking. Each person gets the same file with the same photos.

Does the report include repair prices?

Where our price list has a figure, the report quotes it. For other repairs we write a separate quote so it can travel with a repair request.

Can the seller order the report before listing?

Yes. Many sellers in Garden Grove and Santa Ana do, so the buyer's inspector finds nothing new and the seller decides in advance how to handle each item.

What if the house has a gas fireplace only?

Gas units still vent through a flue or pipe that can crack, rust or block. The report covers the vent path, the burner area and whether a carbon monoxide alarm is in place.

Have a report you can read before the contingency closes

Book the Level 2 on the contact page, listing the address plus each person the copy should go to.